Page 1
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Refer to enclosed warranty for operating parameters to ensure proper use with your water supply.
Watts Premier, Inc. 1725 W. Williams Drive C-20 Phoenix, AZ 85027
Phone: 800-752-5582 www.wattspremier.com Fax: 623-931-0191
Save manual for future reference
Warning
Please read carefully before proceeding with installation. Your failure to follow any attached instructions
or operating parameters may lead to the product’s failure and possible damage to property.
Manual Edition: 08/21/07
P/N 199404
Model: RO-PURE
System Tested and certi ed by WQA against NSF/ANSI
Standard 58 for the reduction of the claims speci ed on the
performance data sheet.
Available From:
®
freshwatersystems.com
serving you since 1989
CLICK HERE
Vue de la page 0
1 2 3 4 5 6 ... 21 22

Résumé du contenu

Page 1 - Model: RO-PURE

Page 1 INSTALLATION, OPERATION AND MAINTENANCE MANUALRefer to enclosed warranty for operating parameters to ensure proper use with your water su

Page 2 - Service Record

Page 10 Drain Saddle fi ts standard 1 ¼” – 1 ½” drain pipesDrain Saddle Installation - Part# 164016Step 17Step 18Step 19Step 20Step 21Te

Page 3 - WARRANTY REGISTRATION

Page 11 How To Use the Quick Connect Fittings For Tubing ConnectionsTo make a connection, the tube is simply pushed into the fi tting.

Page 4

Page 12 Blue Tube Connection (From The RO Module To TANK)Position tank in desired location. Stand it upright or lay it on its side (us

Page 5 - Table of Contents

Page 13 Step 27Red Tube Connection (From FAUCET To The FLOW RESTRICTOR)Determine where the 1/4” red tubing from the faucet and the open

Page 6 - Operational Parameters

Page 14 √ One sediment fi lter (RED Label - 4 Stage Only P/N: 105311)√ One carbon pre-fi lter (YELLOW Label P/N: 105351)√ One carbon post

Page 7

Page 15 Check air pressure only when tank is empty of water!Check air pressure in the tank when you notice a decrease in available wate

Page 8

Page 16 TROUBLE SHOOTINGProblem Cause Solution1. Low/Slow Production Low Water Pressure Assure a minimum of 40 psi incoming

Page 9 - Cold Supply

Page 17 Watts Premier Inc. 1725 W. Williams Drive C-20Phoenix, AZ 85027 USACalifornia Certifi cation # 07-1882RO-Pure System conforms t

Page 10

Page 18 Arsenic (As) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste or odor. It

Page 11 - Available From:

Page 19 Watts Premier has other fi ne water fi ltration products and accessories to enhance your water and to compliment your existing R

Page 12

Page 2 Service RecordDate of Purchase:__________ Date of Install:___________ Installed by:_____________NOTES:DateSedimentFilter(6 month

Page 13 - Start up Instructions

Page 20 Whole House High Performance Water Pressure RegulatorProvides water pressure control solutions for residential, commercial, and

Page 14 - 6 Month System Maintenance

Page 21 Removing chlorine from your showerDeluxe Shower Handle with Built in Filter Replacement fi lters 2PK5-Way Massaging Spray

Page 15 - Parts List

Page 22 Limited WarrantyWhat your Warranty Covers:If any part of your WATTS PREMIER Reverse Osmosis System is defective in workmanship

Page 16 - TROUBLE SHOOTING

Page 3 4 Ways to Register1. On-line at www.wattspremier.com2. Call in your information 1-800-752-55823. Fax in your information 62

Page 17 - Phoenix, AZ 85027 USA

Page 4 Thank you for your purchase of a state of the art Watts Premier Reverse Osmosis (RO) water treatment system. Water quality conce

Page 18 - Arsenic Fact Sheet

Page 5 Thank you for your purchase of a Watts Premier Reverse Osmosis system. With proper installation and maintenance, this system wil

Page 19

Page 6 Hardness: Recommended hardness not to exceed 10 grains per gallon, or 170ppm. System will operate with hardness over 10 grains

Page 20

Page 7 Note:Step 3Step 4Determine desired location for the faucet on your sink and place a piece of masking tape on location where the

Page 21

Page 8 Gather and identify the faucet pieces.Remove faucet base & faucet spout from their respective plastic bags. From above the s

Page 22 - Limited Warranty

Page 9 Hot SupplyCold SupplyAdapta Valve Installation - Part# 134007 Turn off the cold water supply to the faucet by turning the angl